Human Thrombopoietin Quantikine ELISA Kit
Human Thrombopoietin Quantikine ELISA Kit
Human Thrombopoietin Quantikine ELISA Kit

Human Thrombopoietin Quantikine ELISA Kit

 詳情說明

Human Thrombopoietin Quantikine ELISA Kit Summary

深圳子科生物優(yōu)勢代理美國R&DELISA系列產(chǎn)品試劑盒,價格優(yōu)勢,貨期短,歡迎來電咨詢0755-33164177!

貨號:DTP00B

Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (200 uL), Serum (200 uL), EDTA Plasma (200 uL), Heparin Plasma (200 uL)
Sensitivity
18.5 pg/mL
Assay Range
31.2 - 2,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma)
Specificity
Natural and recombinant human Tpo
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human Tpo Immunoassay is a 4.5 hour solid phase ELISA designed to measure human Tpo in cell culture supernates, serum, and plasma. It contains recombinant human Tpo and antibodies raised against the recombinant factor. Results obtained using natural human Tpo showed dose-response curves that were parallel to the standard curves obtained using the recombinant Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for natural Tpo.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Serum, EDTA Plasma, Heparin Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 194 512 983 187 517 970
Standard Deviation 17.5 16.5 26.8 16.3 39.2 63.9
CV% 9 3.2 2.7 8.7 7.6 6.6

Cell Culture Supernates

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 40 40 40
Mean 204 579 1140 203 555 1070
Standard Deviation 13.7 15.1 52.6 19.3 48.7 92.8
CV% 6.7 2.6 4.6 9.5 8.8 8.7

Recovery

The recovery of Tpo spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 99 89-109
Platelet-poor EDTA Plasma (n=4) 95 85-102
Platelet-poor Heparin Plasma (n=4) 93 86-106
Serum (n=4) 102 90-111

Linearity

To assess the linearity of the assay, samples spiked with high concentrations of Tpo were serially diluted with the appropriate Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Human Thrombopoietin/Tpo ELISA Linearity