无码精品动漫在线观看的_成人无码a区在线观看视频_2021免费的一级片_免费完整av片在线播放

/

全國(guó)統(tǒng)一客服熱線:
0755-28715175

產(chǎn)品中心
Product
4產(chǎn)品中心
Human SPARC Quantikine ELISA Kit
Human SPARC Quantikine ELISA Kit
Human SPARC Quantikine ELISA Kit

Human SPARC Quantikine ELISA Kit

 詳情說(shuō)明

 深圳子科生物優(yōu)勢(shì)代理美國(guó)R&DELISA系列產(chǎn)品試劑盒,價(jià)格優(yōu)勢(shì),貨期短,歡迎來(lái)電咨詢0755-33164177!

Human SPARC Quantikine ELISA Kit Summary

貨號(hào):DSP00  規(guī)格:96T

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (10 uL), Serum (10 uL), Platelet-poor EDTA Plasma (20 uL), Platelet-poor Heparin Plasma (20 uL), Human Milk (50 uL)
Sensitivity
0.269 ng/mL
Assay Range
1.6 - 50 ng/mL (Cell Culture Supernates, Serum, Platelet-poor EDTA Plasma, Platelet-poor Heparin Plasma, Human Milk)
Specificity
Natural and recombinant human SPARC
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human SPARC Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human SPARC in cell culture supernates, serum, plasma, and human milk. It contains NS0-expressed recombinant human SPARC and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human SPARC showed linear curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for naturally occurring human SPARC.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Cell Culture Supernates, Serum, Platelet-poor EDTA Plasma, Platelet-poor Heparin Plasma, Human Milk

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 7.34 14.3 29.9 6.65 13.5 28.3
Standard Deviation 0.129 0.282 0.733 0.541 0.989 2.4
CV% 1.8 2 2.5 8.1 7.3 8.5

Recovery

The recovery of SPARC spiked to levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 102 86-111
Platelet-poor EDTA Plasma (n=4) 104 93-111
Platelet-poor Heparin Plasma (n=4) 91 82-100

Linearity

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of SPARC were serially diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay.
Human SPARC ELISA Linearity

Copyright ? 深圳子科生物科技有限公司版權(quán)所有
粵ICP備16056151號(hào)

粵公網(wǎng)安備 44030902000304號(hào)

掃一掃,加關(guān)注

客戶服務(wù)熱線:
0755-33164177
13924667705
18665335907
0755-28715175