Human Hepcidin Quantikine ELISA Kit
Human Hepcidin Quantikine ELISA Kit
Human Hepcidin Quantikine ELISA Kit

Human Hepcidin Quantikine ELISA Kit

 詳情說明

深圳子科生物優(yōu)勢代理美國R&DELISA系列產品試劑盒,價格優(yōu)勢,貨期短,歡迎來電咨詢0755-33164177!

Human Hepcidin Quantikine ELISA Kit Summary

貨號:DHP250    規(guī)格:96T

Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (25 uL), Serum (10 uL), EDTA Plasma (10 uL), Heparin Plasma (10 uL), Urine (10 uL)
Sensitivity
3.81 pg/mL
Assay Range
15.6 - 1,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine)
Specificity
Natural human Hepcidin.
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine Human Hepcidin Immunoassay is a 4.5 hour solid-phase ELISA designed to measure human Hepcidin in cell culture supernates, serum, plasma, and urine. It contains synthetic Hepcidin and antibodies raised against synthetic Hepcidin. This immunoassay has been shown to accurately quantitate synthetic and naturally occurring human Hepcidin.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of components

Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 175 350 726 164 328 647
Standard Deviation 7.51 10.8 23.5 18 26.1 39.8
CV% 4.3 3.1 3.2 11 8 6.2

Recovery

The recovery of human Hepcidin spiked to levels throughout the range of the assay in various matrices was evaluated. Samples were diluted prior to assay.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 111 99-118
EDTA Plasma (n=4) 103 95-115
Heparin Plasma (n=4) 104 93-117
Serum (n=4) 106 96-118

Linearity

To assess the linearity of the assay, samples containing high concentrations of human Hepcidin were serially diluted with Calibrator Diluent to produce samples with values within the dynamic range of the assay. Samples were diluted prior to assay.
Human Hepcidin ELISA Linearity