Human Vitamin D BP Quantikine ELISA Kit
Human Vitamin D BP Quantikine ELISA Kit
Human Vitamin D BP Quantikine ELISA Kit

Human Vitamin D BP Quantikine ELISA Kit

 詳情說(shuō)明


Human Vitamin D BP Quantikine ELISA Kit Summary


貨號(hào):DVDBP0B

規(guī)格:96T

深圳子科生物優(yōu)勢(shì)代理美國(guó)R&DELISA系列產(chǎn)品試劑盒,價(jià)格優(yōu)勢(shì),貨期短,歡迎來(lái)電咨詢0755-33164177!

Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), Serum (10 uL), EDTA Plasma (10 uL), Heparin Plasma (10 uL), Urine (50 uL)
Sensitivity
0.338 ng/mL
Assay Range
6.3 - 100 ng/mL (Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine)
Specificity
Natural and recombinant human Vitamin D BP
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.< 50% cross-species reactivity observed with species tested.
Interference
No significant interference observed with available related molecules.

Product Summary

The Quantikine® Human Vitamin D BP immunoassay is a 3.5 hour sandwich-type solid phase ELISA designed to measure human Vitamin D BP in cell culture supernates, serum, plasma, and urine. It contains HEK293-expressed recombinant human Vitamin D BP and has been shown to accurately quantitate the recombinant factor. Results obtained using natural human Vitamin D BP showed linear curves that were parallel to the standard curves obtained using the Quantikine® kit standards. These results indicate that this kit can be used to determine relative mass values for natural human Vitamin D BP.

Read more about the Vitamin D BP specificity in this White Paper.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested twenty times on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in twenty separate assays to assess inter-assay precision. Assays were performed by at least three technicians using two lots of components

Cell Culture Supernates, Serum, EDTA Plasma, Heparin Plasma, Urine

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 10.9 31.7 63.7 10.1 30.8 61.9
Standard Deviation 0.244 0.423 1.36 0.661 0.664 1.31
CV% 2.2 1.3 2.1 6.5 2.2 2.1

Recovery

The recovery of human Vitamin D BP spiked to three different levels throughout the range of the assay was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Media (n=4) 101 93-117
Urine (n=4) 89 78-96

Linearity

To assess the linearity of the assay, samples containing and/or spiked with high concentrations of human Vitamin D BP were serially diluted with calibrator diluent to produce samples with values within the dynamic range of the assay.
Human Vitamin D BP ELISA Linearity