Mouse/Rat CCL5/RANTES Quantikine ELISA Kit
Mouse/Rat CCL5/RANTES Quantikine ELISA Kit
Mouse/Rat CCL5/RANTES Quantikine ELISA Kit

Mouse/Rat CCL5/RANTES Quantikine ELISA Kit

 詳情說明


Mouse/Rat CCL5/RANTES Quantikine ELISA Kit Summary

深圳子科生物優(yōu)勢代理美國R&DELISA系列產(chǎn)品試劑盒,價格優(yōu)勢,貨期短,歡迎來電咨詢0755-33164177!

貨號:MMR00

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), Serum (25 uL), Platelet-poor EDTA Plasma (25 uL), Platelet-poor Citrate Plasma (25 uL)
Sensitivity
2 pg/mL
Assay Range
7.8 - 500 pg/mL (Cell Culture Supernates, Serum, Platelet-poor EDTA Plasma, Citrate Plasma)
Specificity
Natural and recombinant mouse and rat RANTES.  This assay cross-reacts 1.3% with recombinant Human RANTES.
Cross-reactivity
Cross-reactivity observed with 1 or more available related molecules.Cross-species reactivity observed with 1 or more species tested.
Interference
No significant interference observed with available related molecules.


Product Summary

The Quantikine Mouse/Rat CCL5/RANTES Immunoassay is a 4.5 hour solid phase ELISA designed to measure mouse or rat RANTES levels in cell culture supernates, serum, and platelet-poor plasma. It contains E. coli-expressed recombinant mouse RANTES as well as antibodies raised against the recombinant factor. This immunoassay has been shown to accurately quantitate recombinant RANTES. Results obtained using natural mouse or rat RANTES showed linear curves that were parallel to the standard curves obtained using the recombinant kit standards. These results indicate that this kit can be used to determine relative mass values for natural mouse and rat RANTES.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Cell Culture Supernates, Serum, Platelet-poor EDTA Plasma, Citrate Plasma, Platelet-poor Citrate Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 18.8 104 198 20.1 109 208
Standard Deviation 0.7 1.9 4.1 1.6 5.6 11.5
CV% 3.7 1.8 2.1 8 5.1 5.5

Recovery

The recovery of RANTES spiked to three levels in mouse samples throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Cell Culture Supernates (n=8) 108 98-115
Platelet-poor Citrate Plasma (n=5) 102 95-110
Platelet-poor EDTA Plasma (n=5) 99 86-110
Serum (n=5) 97 90-107

Linearity

To assess the linearity of the assay, four or more samples containing or spiked with various concentrations of RANTES in each matrix were diluted with Calibrator Diluent and then assayed.
Mouse/Rat CCL5/RANTES ELISA Linearity
Mouse/Rat CCL5/RANTES ELISA Linearity