Mouse/Rat Leptin Quantikine ELISA Kit
Mouse/Rat Leptin Quantikine ELISA Kit
Mouse/Rat Leptin Quantikine ELISA Kit

Mouse/Rat Leptin Quantikine ELISA Kit

 詳情說明

Mouse/Rat Leptin Quantikine ELISA Kit Summary

貨號(hào):MOB00

Assay Type
Solid Phase Sandwich ELISA
Format
96-well strip plate
Assay Length
4.5 hours
Sample Type & Volume Required Per Well
Cell Culture Supernates (50 uL), Serum (20 uL), EDTA Plasma (20 uL)
Sensitivity
22 pg/mL
Assay Range
62.5 - 4,000 pg/mL (Cell Culture Supernates, Serum, EDTA Plasma)
Specificity
Natural and recombinant mouse and rat Leptin.  This assay cross-reacts 0.24% with Human Leptin.
Cross-reactivity
< 0.5% cross-reactivity observed with available related molecules.Cross-species reactivity observed with 1 or more species tested.
Interference
Interference observed with 1 or more available related molecules.

Product Summary

The Quantikine Mouse Leptin Immunoassay is a 4.5 hour solid phase ELISA designed to measure soluble mouse leptin in cell culture supernates, serum*, and plasma. It contains recombinant mouse leptin expressed in E. coli and antibodies raised against the recombinant factor. This immunoassay has been shown to quantitate the recombinant mouse leptin accurately. Results obtained measuring natural mouse leptin showed dose-response curves that were parallel to the standard curves obtained using the Quantikine kit standards. These results indicate that this kit can be used to determine relative mass values for natural mouse leptin.

*Pregnant mouse serum from the second trimester of pregnancy through post-partum day 1 require acid/urea activation of mouse leptin.

Precision

Intra-Assay Precision (Precision within an assay) Three samples of known concentration were tested on one plate to assess intra-assay precision
Inter-Assay Precision (Precision between assays) Three samples of known concentration were tested in separate assays to assess inter-assay precision

Cell Culture Supernates, Serum, EDTA Plasma

Intra-Assay Precision Inter-Assay Precision
Sample 1 2 3 1 2 3
n 20 20 20 20 20 20
Mean 182 693 1803 187 654 1736
Standard Deviation 7.9 22.6 67.9 14.2 30.5 87.4
CV% 4.3 3.3 3.8 7.6 4.7 5

Recovery

The recovery of mouse/rat Leptin spiked to three levels throughout the range of the assay in various matrices was evaluated.

Sample Type Average % Recovery Range %
Mouse Cell Culture Supernates (n=5) 101 85-120
Mouse EDTA Plasma (n=4) 92 78-105
Mouse Heparin Plasma (n=4) 95 81-105
Mouse Serum (n=18) 108 81-122
Rat Cell Culture Supernates (n=4) 114 103-125
Rat EDTA Plasma (n=7) 96 83-114
Rat Serum (n=10) 92 81-115

Linearity

To assess the linearity of the assay, four or more samples containing and/or spiked with high concentrations of mouse/rat Leptin in each matrix were diluted with Calibrator Diluent and then assayed.

Mouse/Rat Leptin/OB ELISA Linearity